Address: l00 Southgate Parkway
Morristown, New Jersey 07960
(Morris County)
Location: Intersection of James Street, Blackberry Lane and 287 North access ramp. Immediate access from I-287 North and South via Harter Road
Owner/Developer: Blackberry Lane Associates
c/o M. Alfieri Co, Inc
399 Thornall Street, P.O. Box 2911
Metropark (Edison), New Jersey 08818-2911
Architect: M. Alfieri Co., Inc.
Contractor: M. Alfieri Co., Inc.
Management: M. Alfieri Co., Inc.
Building: 150,000 rentable square feet.
Type of Construction: Steel frame and concrete floors on metal decking and steel joists
Building Exterior: Continuous strip of one-inch solar bronze-tinted insulating glass with precast concrete panels and three-story solar glass atrium wall
Lobby: Three (3) story atrium
Floor Rentable Square Feet
First 50,000 SF
Second 50,000 SF
Third 50,000 SF
Doors: On the First Floor, wood solid core painted doors at common areas, wood solid core painted doors for tenant entry and solid core ash doors for the tenant premises. On the upper floors, glass doors for tenant entry and solid core ash doors for the tenant premises.
Windows:
Floor To Sill Height
First 7'2"w x 5'8"h 21"
Second 87-1/2"w x 44-1/2"h
Third 87-1/2"w x 44-1/2"h
Ceiling: Building standard 2' x 4' grid and tiles in lobbies and 2' x 4' exposed grid in tenant space
Lighting: 2' x 4' T-8 with parabolic lenses
Floor Load: 100 lbs per square foot
(80 lbs per sq ft live load, 20 lbs per sq ft partitions)
Elevators: Three door elevators with platforms, entrances and doors. Elevators have a passenger capacity of 2,500 lbs.
Parking: 4 spaces per 1,000 SF; asphalt parking surface.
HVAC System:
HEAT: PACE Perimeter Heat Control System consists of perimeter baseboards, master control panel, SCR controller, night setback, solar sensors and zone override
A/C: Westinghouse chiller 450 tons
Electric: GPU Energy 2,400 amps (800 amps per floor) 14.5 total watts per sq ft, including 8 watts per sq ft for tenant's office/data/computer equipment
Communications: Building has both fiber cables and ISDN service by AT& T, but extent and serviceability as to suitability of purpose has not been determined
Water: SMCMUA , 4" main domestic, 8" Main Fire pumps
Safety System: Fully sprinklered building water Fire Alarm System with staged evacuation capability, voice enunciator and paging, smoke detectors, pullstations and handsets for common areas, strobe lights and stairwell pressurization fans.
Amenities: In-house food service/café, Half-mile to Loantaka County Park system, Two miles to Morristown center shopping and restaurants, Minutes to major hotels and conference center, , Courier service drop
Corporate Neighbors: Honeywell
Verizon
AT&T
UPS
Telcordia
|
|